2024 Correct and Up-to-date EMC D-VXR-DY-23 BrainDumps [Q158-Q182]

Share

2024 Correct and Up-to-date EMC D-VXR-DY-23 BrainDumps

Current D-VXR-DY-23 dumps Preparation through Our Practice Test

NEW QUESTION # 158
View the Exhibit.

You are reviewing a VxRail Pre-Installation Site Checklist.
What conclusion can be drawn about the VxRail deployment from the exhibit?

  • A. Top of Rack (ToR) switches will use two uplink ports
  • B. Upstream switches will have two ISLs
  • C. Two Upstream switches will be used
  • D. Two Top of Rack (ToR) switches will be used

Answer: B


NEW QUESTION # 159
What is validated by running the Proactive VM Creation test in vCenter on a VxRail cluster?

  • A. vSAN has sufficient storage capacity
  • B. vSAN operates successfully
  • C. Network firewalls are configured correctly
  • D. Network performance is sufficient

Answer: B


NEW QUESTION # 160
A customer requires a Stretched VxRail Cluster with S570 nodes in its minimal configuration.
Which setup will fulfill the requirement?

  • A. 4+4 nodes
  • B. 3+3 nodes
  • C. 6+6 nodes
  • D. 2+2 nodes

Answer: B


NEW QUESTION # 161
What is a consideration when performing a VxRail software upgrade from version 4.7.xxx to version 7.0.xxx?

  • A. VxRail Manager VM must be changed to the default name to avoid an upgrade failure
  • B. Secure boot must be enabled on the ESXi hosts for a successful upgrade
  • C. External vCenter server must be upgraded after the VxRail is upgraded
  • D. vCenter Server requires a temporary IP address on a different subnet before the upgrade

Answer: D


NEW QUESTION # 162
A company has recently implemented a popular date center monitoring and reporting software solution. They plan to use the solution to consolidate reporting into a single platform.
What is an expected benefit of programmatically gathering VxRail information?

  • A. Perform pre-checks for vSAN health
  • B. Automate iDRAC firmware management and status
  • C. Perform node shutdowns and specific operations
  • D. Obtain status of all running operations on a cluster

Answer: D


NEW QUESTION # 163
Which requirement is optional for a VxRail Stretched Cluster?

  • A. Cross-site layer-2 connectivity
  • B. Enterprise Plus vSphere Licensing
  • C. IPv6 Multicast between locations
  • D. External vCenter

Answer: C


NEW QUESTION # 164
A company has a simple, 4 node VxRail cluster. The VxRail is running version 3.5 and utilizes a vSphere standard license. The company has asked for a VxRail software upgrade.
What are the steps for the upgrade?

  • A. Contact Dell EMC support to request the upgrade to the VxRail cluster.
  • B. Log in to support.emc.com and download the upgrade packages.
  • C. Log in to VxRail Manager, select "Internet Upgrade", then follow the prompts.
  • D. Place all four nodes into maintenance mode.

Answer: B


NEW QUESTION # 165
You are asked to cable up a VxRail G Series cluster to a redundant pair of 1/10G switches.
What is the cabling best practice for this configuration?

  • A. Cable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch. Cable BMC from node 1 and 3 to one switch. Cable BMC from node 2 and 4 to the
  • B. Cable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch. Cable BMC from node 1 and 2 to one switch. Cable BMC from node 3 and 4 to the other switch.
  • C. Cable ports 1 and 3 to one switch. Cable ports 2 and 4 to the other switch.
  • D. Cable ports 1 and 2 to one switch. Cable ports 3 and 4 to the other switch.

Answer: A


NEW QUESTION # 166
When the Network Services Validation is enabled, what does the VxRail NVT validate?

  • A. IP address conflicts, NTP, and DNS settings
  • B. STP and VLAN configurations
  • C. VLAN configurations, NTP, and DNS settings
  • D. VLAN configurations and port mode settings

Answer: A


NEW QUESTION # 167
At which levels of SSD remaining write endurance does the health status change from Healthy to Warning - Error - Critical?

  • A. 20% - 10% - 3%
  • B. 10% - 5% - 1%
  • C. 50% - 30% - 10%
  • D. 30% - 20% - 5%

Answer: D


NEW QUESTION # 168
An implementation engineer is configuring the network firewall to support a VxRail installation.
Where can they find the necessary firewall rules?

  • A. Network Validation Tool
  • B. Rack worksheet of the Network PEQ
  • C. VxRail Configuration Portal
  • D. As-Built Configuration Report

Answer: D


NEW QUESTION # 169
Which VxRail model(s) has a non-mirrored IDSDM?

  • A. D560/F
  • B. All E Series
  • C. All G Series
  • D. S570

Answer: C


NEW QUESTION # 170
VxRail Validation is failing for a deployment engineer during initialization. The error states that Node 1 cannot reach Node 2 on the Management network. While investigating the issue, the deployment engineer is unable to ping the management network default gateway.
Which step in the VxRail Configuration Portal should have been followed to prevent the situation?

  • A. The Pre-Deployment Checklist should have been reviewed and issues resolved.
  • B. The NIC Configuration must be set to 4x25GbE to support the network devices.
  • C. The cluster should have been configured with two virtual distributed switches.
  • D. The VxRail Manager and vCenter server must be logically separated on different subnets.

Answer: A


NEW QUESTION # 171
A customer is running a 5-node VxRail all flash cluster with vSAN advanced licensing. They are unable to apply a RAID-6 Erasure Coding storage policy to the VMs.
What could be the cause?

  • A. VxRail cluster only supports mirroring with an FTT of 1.
  • B. Incorrect number of failure domains in the cluster.
  • C. RAID-6 Erasure Coding is only supported with stretched clusters.
  • D. vSAN license level is incorrect and needs upgrading.

Answer: B


NEW QUESTION # 172
What is the recommended format for host names when using the VxRail Deployment Wizard for an External vCenter solution?

  • A. Host name for vCenter Server - FQDN for VxRail Manager
  • B. FQDN for vCenter Server - Host name for VxRail Manager
  • C. Host name for both vCenter Server and for VxRail Manager
  • D. FQDN for both vCenter Server and for VxRail Manager

Answer: B


NEW QUESTION # 173
What is a Dell EMC converged platform product?

  • A. VxRack
  • B. Vblock/VxBlock
  • C. Vscale Architecture
  • D. VxRail

Answer: B


NEW QUESTION # 174
What is the default IP address of the VxRail Manager?

  • A. 192.168.10.16
  • B. 192.168.10.200
  • C. 192.168.1.16
  • D. 192.168.1.200

Answer: B


NEW QUESTION # 175
What is the Dell EMC recommendation for VxRail Management VLANs?

  • A. Configure the VLAN ID with a default of 3940
  • B. Use untagged traffic on the Native VLAN for the Public Management network
  • C. Configure the VLAN ID with a default of 1
  • D. Use tagged traffic on the Native VLAN for the Public Management network

Answer: B


NEW QUESTION # 176
When using VxRail Manager, what is the source of information that can help validate good VxRail system post-deployment status?

  • A. System Diagnostic, Events, Health Logical View, Health Physical View, Log Bundle
  • B. Last Heartbeat, Last Configuration Sent, Network Environment Settings, Cluster Monitor
  • C. MARVIN-Virtual-SAN-Cluster > Monitor > Virtual SAN > Health
  • D. MARVIN-Virtual-SAN-Cluster > Manage > Health and Performance

Answer: A


NEW QUESTION # 177
The Market Place on a VxRail Manager is empty on a newly deployed system. Testing shows that the Internet is reachable through proxy in the management network.
Which action should be taken to correct this situation?

  • A. VxRail Manager has no proxy support.
  • B. Upgrade to latest version and add proxy configuration manually.
  • C. Manually add the proxy information in the VxRail Manager configuration
  • D. Reset the appliance and redeploy with proxy information filled in the deployment process.

Answer: C


NEW QUESTION # 178
Which license must be provided by the customer for a VxRail deployment with embedded vCenter?

  • A. RecoverPoint
  • B. VMware Log Insight
  • C. VxRail Manager
  • D. VMware vSphere

Answer: D


NEW QUESTION # 179
After finishing the rack and stack of a VxRail Model G410 cluster, in which sequence should the nodes be powered on?

  • A. Any order possible
  • B. Forward order (1 - 4)
  • C. All four at the same time
  • D. Reverse order (4 - 1)

Answer: D


NEW QUESTION # 180
What accurately describes the positioning of a VxRail?

  • A. Software defined solution with rack scale and integrated networking
  • B. Can start small and grow to hundreds of nodes
  • C. Can start small and grow with a low entry cost
  • D. Converged architecture with enterprise grade resiliency

Answer: D


NEW QUESTION # 181
How can an administrator limit IPv6 traffic created by VxRail nodes?

  • A. Create a unique VLAN for IPv6 traffic
  • B. Tag VLAN 3939 on the ToR switches
  • C. Enable MLD snooping and querier
  • D. Configure Link Aggregation

Answer: C


NEW QUESTION # 182
......

100% Reliable Microsoft D-VXR-DY-23 Exam Dumps Test Pdf Exam Material: https://passking.actualtorrent.com/D-VXR-DY-23-exam-guide-torrent.html