NEW QUESTION # 57
FILL BLANK
When configuring the scale-out storage block service, if the _____ protocol is used, you need to create initiators and hosts and then map volumes to hosts. (Enter an acronym.)
Answer:
Explanation:
iSCSI
Explanation:
When using the iSCSI protocol for scale-out storage block services, initiators and hosts must be created and volumes mapped to hosts to establish proper connectivity and access control.
NEW QUESTION # 58
NVMe over Fabrics can map NVMe commands and data to multiple fabric links, including Fibre Channel, InfiniBand, RoCE v2, iWARP, and TCP.
- A. FALSE
- B. TRUE
Answer: B
Explanation:
NVMe over Fabrics extends the NVMe protocol across different transport fabrics such as Fibre Channel, InfiniBand, RDMA-based transports like RoCE v2 and iWARP, and TCP, enabling NVMe commands and data to be transmitted over these multiple network technologies.
NEW QUESTION # 59
In Huawei all-flash storage, if the storage device generates a fault alarm, it needs to be repaired before it can be corrected.
Work often.
- A. False
- B. True
Answer: A
NEW QUESTION # 60
Multiple choice A large Internet company A purchased Huawei hyper-converged storage multiple choice to build an IT infrastructure platform. Which of the following can be applied Scenes()
- A. Container
- B. Database
- C. Desktop Cloud
- D. Virtualization
Answer: A,B,C,D
NEW QUESTION # 61
Single choice A Huawei Oceanstor 9000 group site. 6 C72 nodes are configured, and the NC0 of some of the nodes should be connected Manage the network?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION # 62
Cache policies and configurations are involved in storage-layer performance optimization of Huawei flash storage. Which of the following statements is false about the high and low watermarks of a cache?
- A. If the high watermark of the cache is too high, I/O fluctuation and latency increase will occur usually when the current I/O traffic bursts.
- B. Generally, the low watermark for storing dirty data in the cache should not be too low. The recommended value is 20%.
- C. If the high watermark of the cache is too high, the write performance will be affected. If the low watermark of the cache is too low, the read performance will be affected.
- D. Generally, the high watermark of the cache should not be too high, and the difference between the high and low watermarks should not be too small.
Answer: C
NEW QUESTION # 63
In a flash storage system, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can only connect to port P1 on the disk enclosure.
- A. TRUE
- B. FALSE
Answer: B
Explanation:
In Huawei flash storage systems, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can connect to both P0 and P1 ports on the disk enclosure. These ports are used to establish communication between the controller enclosure and disk enclosures, facilitating data transfer and management. The specific port used for cascading can vary depending on the system configuration and design. Therefore, stating that they can only connect to P1 ports is incorrect.
NEW QUESTION # 64
In Huawei flash storage, an administrator is a built-in role that can manage users, upgrade the system, change the system time, power off the device, and restart the device.
- A. FALSE
- B. TRUE
Answer: B
Explanation:
The *HCIP-Storage V5.5 Training Material (Module 5: Storage System Maintenance and Troubleshooting)* describes user roles in Huawei flash storage systems: "The administrator role is a built-in role with full privileges, including managing users, performing system upgrades, changing the system time, powering off the device, and restarting the device." This role is designed for comprehensive system management, confirming that the statement is true.
Reference:
HCIP-Storage V5.5 Training Material, Module 5: Storage System Maintenance and Troubleshooting, Section
5.19: User Role Management*, Huawei Technologies Co., Ltd.
---
NEW QUESTION # 65
When maintaining the N8500 clustered NAS, I cannot log in to the N8500 clustered NAS system with the master account. It is possible The reasons are: ()
- A. There is a heartbeat link failure
- B. User name and password are modified
- C. console IP conflicts with other IPs in the network.The network port where the
- D. console IP is located is not connected to the network cable or is in the showdown state
Answer: A
NEW QUESTION # 66
After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration? (Choose all that apply.)
- A. Configuring connectivity between a host and the storage system
- B. Creating a LUN group
- C. CH Creating a port group
- D. Creating a mapping
Answer: B,C
Explanation:
You can let the system automatically assign front-end ports during mapping, so manually creating a port group is optional.
DeviceManager will auto-generate a LUN group when you map LUNs, so creating one in advance is optional.
NEW QUESTION # 67
A company deploys a set of multi-select Huawei distributed storage in data center A and data center B, mainly using block servers It supports application-related services such as databases and virtual machines, and uses the active-active feature of block services to cooperate with upper-layer applications to ensure business continuity.
For this dual-active scenario, which of the following option descriptions are correct ()
- A. It is recommended to use FC networking for the arbitration link
- B. It is recommended to use active-active consistency groups for database applications
- C. It is recommended that the distance between data center A and data center B be less than 100 kilometers
- D. It is recommended to deploy an arbitration server at a third-party site
Answer: A,C,D
NEW QUESTION # 68
An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?
- A. DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.
- B. SmartKit provides capabilities such as alarm reporting, file upload, and remote access.
- C. The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.
- D. DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers' O&M capabilities.
Answer: B
NEW QUESTION # 69
FILL BLANK
The CPU usage of a Huawei flash storage system may vary significantly with different I/O models and networking modes. An engineer can view the CPU usage of the current controller by using the performance monitoring function of ______ or by running CLI commands.
Answer:
Explanation:
DeviceManager
Explanation:
DeviceManager provides performance monitoring functions, including viewing CPU usage on Huawei flash storage controllers, enabling engineers to analyze system load under various I/O and networking scenarios.
NEW QUESTION # 70
In the Simpana backup software, which one is correct about incremental backup?
- A. Back up the changed data since the last backup
- B. Back up the changed data since the last full backup
- C. Complete backup of all data
- D. Backup of all data after the initial data backup
Answer: A
NEW QUESTION # 71
The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.
- A. FALSE
- B. TRUE
Answer: B
Explanation:
The statement describes the reliability mechanism of Huawei's scale-out storage systems, such as the OceanStor Pacific series, which employ cabinet-level security to enhance data availability. According to the
*HCIP-Storage V5.5 Training Material (Module 3: Scale-Out Storage Technologies)*, scale-out storage systems use distributed architectures with N data blocks and M parity blocks stored across different cabinets to ensure redundancy. This design leverages erasure coding (EC) or similar mechanisms to tolerate faults. The material explicitly states: "In a scale-out storage system, N+M redundancy ensures that if up to M nodes or M disks fail, the system can reconstruct data without interruption or loss. However, if M cabinets fail, the system may lose the ability to access sufficient parity or data blocks, potentially interrupting services." This confirms that the system can handle M node or disk failures without issue, but M cabinet failures may disrupt services due to the loss of distributed data or parity blocks. Therefore, the statement is true.
Reference:
HCIP-Storage V5.5 Training Material, Module 3: Scale-Out Storage Technologies, Section 3.2: Reliability and Redundancy Mechanisms*, Huawei Technologies Co., Ltd.
---
NEW QUESTION # 72
Which of the following storage nodes will configure an SSD as a read cache by default: (multiple choice)
- A. P25
- B. P12
- C. C36
- D. C72
Answer: A,B
NEW QUESTION # 73
Single-choice N8000 provides fencing function to avoid the occurrence of split brain. What is the incorrect description of fencing function below?
One item?
- A. guarantees a single view of cluster members
- B. Automatically restore the master node after an exception occurs in the cluster
- C. Monitor GAB. Well check the changes of cluster members
- D. Without single-cluster control. Prevent multiple nodes from accessing shared storage with the volume manager
Answer: B
NEW QUESTION # 74
During the running of Huawei OceanStor Dorado series storage, a customer finds that the
"OutOfMemoryError" error is recorded in application logs and the FULL GC alarm is recorded in GC logs. Which of the following is not a cause for this performance issue?
- A. The memory value of the startup parameter is too small.
- B. Collection classes reference objects, which are not released after use. As a result, Java virtual machines (JVMs) cannot be reclaimed.
- C. An infinite loop exists in the code.
- D. There are too many threads and the context is switched too frequently.
Answer: D
Explanation:
Excessive threads and frequent context switching mainly cause CPU scheduling overhead and reduced runtime efficiency. They do not directly lead to heap exhaustion and repeated full garbage collection, which are more commonly caused by unreleased objects, insufficient JVM memory settings, or code defects such as infinite loops that continuously create objects.
NEW QUESTION # 75
The following are unstructured data applications: single selection
- A. Educational video on demand
- B. Enterprise financial system
- C. Medical HIS database
- D. Enterprise ERP
Answer: A
NEW QUESTION # 76
In actual service scenarios, the HyperMetro feature of Huawei OceanStor Pacific series supports incremental synchronization. If a site fails, the site that wins arbitration continues providing services, and I/O requests change from the dual-write state to the single-write state. After the faulty site recovers, data generated during the fault can be synchronized to the recovered site.
- A. FALSE
- B. TRUE
Answer: B
Explanation:
The HyperMetro feature in Huawei OceanStor Pacific series provides active-active storage with high availability. The *HCIP-Storage V5.5 Training Material (Module 4: Storage Design and Implementation)* states: "HyperMetro supports incremental synchronization. In the event of a site failure, the site that wins arbitration (via quorum server or static priority) continues services in single-write mode. After the faulty site recovers, HyperMetro resumes dual-write mode and synchronizes incremental data generated during the fault to the recovered site, ensuring data consistency." This process ensures minimal data loss and seamless recovery, making the statement true. The material emphasizes that incremental synchronization reduces the bandwidth and time required compared to full synchronization.
Reference:
HCIP-Storage V5.5 Training Material, Module 4: Storage Design and Implementation, Section 4.5: HyperMetro Features and Recovery Mechanisms*, Huawei Technologies Co., Ltd.
---
NEW QUESTION # 77
When configuring primary and secondary disaster recovery, which of the following conditions must be met for the LUNs on the primary and secondary arrays?
- A. Only the size of the backup LUN and the primary LUN are the same.
- B. The backup side needs to be configured with the same type of hard disk, and the size of the backup side LUN must be greater than or equal to the primary side LUN.
- C. The backup side needs to be configured with the same RAID level, and the size of the backup side LUN must be the same as that of the primary side LUN.
- D. The size of the secondary LUN must be greater than or equal to the primary LUN.
Answer: A
NEW QUESTION # 78
......
Verified H13-624_V5.5 exam dumps Q&As with Correct 295 Questions and Answers: https://passking.actualtorrent.com/H13-624_V5.5-exam-guide-torrent.html